On Tue, Apr 09, 2024 at 10:52:45AM +0200, Karel Lucas wrote:
> I defined the table as stated in your book (3rd edition, page 42). However,
> that gives an error message. In the lines with that table: macro 'martians'
> not defined. Moreover, I now also have a Syntax error in lines 38, 39 and
> 46, causing the pf lines not to be loaded.
macro names are case sensitive, to wit
peter@kapet:~$ cat martians
Martians = "{ 127.0.0.0/8, 192.168.0.0/16, 172.16.0.0/12, \
10.0.0.0/8, 169.254, 0.0/16, 192.0.2.0/24, \
0.0.0.0/8, 240.0.0.0/4 }"
block from $martians
peter@skapet:~$ doas pfctl -vnf martians
Martians = "{ 127.0.0.0/8, 192.168.0.0/16, 172.16.0.0/12, 10.0.0.0/8, 169.254, 0.0/16, 192.0.2.0/24, 0.0.0.0/8, 240.0.0.0/4 }"
martians:5: macro 'martians' not defined
martians:5: syntax error
for conversion to tables, keep in mind that references need the
surrounding '<' and '>'.
--
Peter N. M. Hansteen, member of the first RFC 1149 implementation team
https://bsdly.blogspot.com/ https://www.bsdly.net/ https://www.nuug.no/
"Remember to set the evil bit on all malicious network traffic"
delilah spamd[29949]: 85.152.224.147: disconnected after 42673 seconds.